玻璃绝缘子英文标准,全国咨询电话:400-66666-10 手机:15810505050 企业VIP
Standard suspension insulator Fog type suspension insulator Open Air Profile type suspension insulator Cap and Pin type suspension insulator
LXHP-70
Fog type suspension insulator Zoom in
LXHP-70 Fog type suspension insulator Currency designation U70BP/146H U70BP/146H U70BP/146H Jinlihua designation LXHP4-160 LXHP5-160 LXHP6-160 ( mm )Diameter D 255 280 320 ( mm )Spacing H 146 146 146 ( mm )Creepage L 400 450 550 ( mm )Socket soupling 16 16 16 ( kN )Mechanical failing load 70 70 70 ( kN )Mechanical routine test 35 35 35 ( kV )Wet power frequency withstand voltage 45 45 45 ( kV )Dry lightning impulse withstand voltage 110 125 140 ( P.U )Impulse puncture voltage 2.8 2.8 2.8 ( kV )Power frequency puncture voltage 130 130 130 ( µV )Rodio influence voltage 50 50 50 ( kV )Electric iron visual test 18/22 18/22 18/22 Power frequency electric arc voltage 0.12s/20kA 0.12s/20kA 0.12s/20kA ( kg )Net weight per unit 4.6 5.8 9.2
LXHP-100 Fog type suspension insulator Currency designation U100BP/146H U100BP/146H U100BP/146H Jinlihua designation LXHP3-100 LXHP4-100 LXHP6-100 ( mm )Diameter D 260 280 320 ( mm )Spacing H 146 146 146 ( mm )Creepage L 400 450 550 ( mm )Socket soupling 16 16 16 ( kN )Mechanical failing load 100 100 100 ( kN )Mechanical routine test 50 50 50 ( kV )Wet power frequency withstand voltage 45 45 45 ( kV )Dry lightning impulse withstand voltage 110 125 140 ( P.U )Impulse puncture voltage 2.8 2.8 2.8 ( kV )Power frequency puncture voltage 130 130 130 ( µV )Rodio influence voltage 50 50 50 ( kV )Electric iron visual test 18/22 18/22 18/22 Power frequency electric arc voltage 0.12s/20kA 0.12s/20kA 0.12s/20kA ( kg )Net weight per unit 5.4 5.8 9.2
LXP-70 Standard suspension insulator
Zoom in
LXP-70 Standard suspension insulator Currency designation U70B/140 U70B/146 U70B/127 Jinlihua designation LXP3-70 LXP1-70 LXP2-70 ( mm )Diameter D 255 255 255 ( mm )Spacing H 140 146 127 ( mm )Creepage L 320 320 320 ( mm )Socket soupling 16 16 16 ( kN )Mechanical failing load 70 70 70 ( kN )Mechanical routine test 35 35 35 ( kV )Wet power frequency withstand voltage 40 40 40 ( kV )Dry lightning impulse withstand voltage 100 100 100 ( P.U )Impulse puncture voltage 2.8 2.8 2.8 ( kV )Power frequency puncture voltage 130 130 130 ( µV )Rodio influence voltage 50 50 50 ( kV )Electric iron visual test 18/22 18/22 18/22 Power frequency electric arc voltage 0.12s/20kA 0.12s/20kA 0.12s/20kA ( kg )Net weight per unit 3.6 3.6 3.5

| 型 号 |
品 号 |
机械破坏 负荷 kN 不小于 |
打击破 坏负荷 N.cm 不小于 |
1h机电 负荷 试验值 kN |
公称 结构 高度 H |
绝缘件 公称 直径 D |
最小 公称 爬电 距离 |
雷电全 波冲击 耐受电压 (峰值) kv, 不小于 |
工频电压 (有效值) kv, 不小于 |
单件重量 kg |
| mm |
1min 湿耐受 |
击穿 |
LXY-70 LXY1-70 |
132202 |
70 70 |
565 565 |
52.5 52.5 |
127 146 |
255 255 |
320 320 |
100 100 |
40 40 |
130 130 |
3.77 3.78 |
| LXY-100 |
133201 |
100 |
678 |
75.0 |
146 |
255 |
320 |
100 |
40 |
130 |
4.10 |
| LXY-120 |
134205 |
120 |
678 |
90.0 |
146 |
255 |
320 |
100 |
40 |
130 |
4.20 |
| LXY3-160 |
135013 |
160 |
1017 |
120.0 |
155 |
280 |
380 |
105 |
42 |
130 |
6.20 |
| LXY3-210 |
136202 |
210 |
1017 |
157.5 |
170 |
280 |
390 |
105 |
42 |
130 |
6.70 |
| LXY-240 |
136206 |
240 |
1017 |
180.0 |
170 |
280 |
390 |
105 |
42 |
130 |
6.80 |
| LXY3-300 |
137201 |
300 |
1017 |
225.0 |
195 |
320 |
485 |
110 |
45 |
130 |
10.7 |

| 型 号 |
品 号 |
机械破坏负荷kN不小于 |
打击破坏负荷N.cm 不小于 |
1h机电负荷 试验值kN |
公称结构高度 H |
绝缘件 公称直径 D |
最小公称爬电距离 |
50%雷电冲击耐受电压(峰值)kv,不小于 |
工频电压(有效值)kv,不小于 |
单件重量 kg |
| mm |
湿耐受 |
击穿 |
LXHY4-70 LXHY-70 |
132605 132608 |
70 70 |
565 565 |
52.5 52.5 |
146 160 |
255 255 |
400 400 |
120 120 |
45 45 |
130 130 |
4.80 4.80 |
| LXHY5-70 |
132603 |
70 |
565 |
52.5 |
146 |
280 |
450 |
130 |
45 |
130 |
5.30 |
| LXHY4-100 |
133602 |
100 |
678 |
75.0 |
146 |
280 |
450 |
130 |
45 |
130 |
5.40 |
| LXHY4-120 |
134602 |
120 |
678 |
90.0 |
146 |
280 |
450 |
130 |
45 |
130 |
5.50 |
LXHY3-160 LXHY4-160 |
135605 135606 |
160 160 |
1017 1017 |
120.0 120.0 |
155 170 |
280 280 |
450 450 |
130 130 |
50 50 |
130 130 |
7.00 7.00 |
LXHY5-160 LXHY6-160 |
135603 135607 |
160 160 |
1017 1017 |
120.0 120.0 |
170 155 |
320 320 |
545 545 |
130 130 |
55 55 |
130 130 |
8.80 8.90 |
| LXHY3-210 |
136201 |
210 |
1017 |
157.5 |
170 |
320 |
545 |
130 |
55 |
130 |
9.23 |
| LXHY-300 |
137202 |
300 |
1017 |
225.0 |
195 |
340 |
545 |
140 |
55 |
130 |
12.20 |
| LXHY3-300 |
|
300 |
1017 |
225.0 |
195 |
380 |
635 |
155 |
60 |
130 |
14.30 |

| 型 号 |
品 号 |
机械 破坏 负荷 kN 不小于 |
打击 破坏 负荷 N.cm 不小于 |
1h机电 负荷 试验值 kN |
公称 结构 高度 H |
绝缘件 公称 直径 D |
最小公 称爬电 距离 |
雷电全 波冲击 耐受电 压(峰值)kv, 不小于 |
直流1min湿 耐受电 压(峰值)kv, 不小于 |
工频击 穿电压(有效值)kv, 不小于 |
单件 重量 kg |
| mm |
| LXZY-160 |
135901 |
160 |
10 |
120.0 |
170 |
320 |
545 |
140 |
65 |
130 |
9.6 |
| LXZY-210 |
136901 |
210 |
10 |
157.5 |
170 |
320 |
545 |
140 |
65 |
130 |
10.0 |
| LXZY-300 |
137901 |
300 |
10 |
225.0 |
195 |
400 |
635 |
150 |
70 |
140 |
14.3 |
| LXZY1-300 |
|
300 |
10 |
225.0 |
195 |
340 |
545 |
140 |
65 |
140 |
14.3 |

| 型 号 |
品 号 |
机械破坏负荷kN不小于 |
打击破坏负荷N.cm 不小于 |
1h机电负荷 试验值kN |
公称结构高度 H |
绝缘件 公称直径 D |
最小公称爬电距离 |
50%雷电冲击闪络电压(峰值)kv,不小于 |
工频电压(有效值)kv,不小于 |
单件重量 kg |
| mm |
湿闪络 |
击穿 |
| LXQY-120 |
134014 |
120 |
678 |
90.0 |
140 |
255 |
305 |
100 |
45 |
120 |
4.10 |
| LXQY-120 |
134015 |
120 |
678 |
90.0 |
146 |
255 |
305 |
100 |
45 |
120 |
4.11 |

| 型 号 |
品 号 |
机械破坏负荷kN不小于 |
打击破坏负荷N.cm 不小于 |
1h机电负荷 试验值kN |
公称结构高度 H |
绝缘件 公称直径 D |
最小公称爬电距离 |
50%雷电冲击闪络电压(峰值)kv,不小于 |
工频电压(有效值)kv,不小于 |
单件重量 kg |
| mm |
湿闪络 |
击穿 |
LXAY-120 LXAY1-120 |
134012 134016 |
120 120 |
678 678 |
90.0 90.0 |
146 140 |
390 390 |
360 360 |
100 100 |
50 50 |
120 120 |
5.30 5.30 |
| LXAY-160 |
135012 |
160 |
1017 |
120.0 |
146 |
390 |
360 |
100 |
50 |
120 |
7.00 |
| LXAY-210 |
|
210 |
1017 |
157.5 |
160 |
390 |
350 |
100 |
50 |
120 |
7.47 |

| 型 号 |
机械破坏负荷kN不小于 |
打击破坏负荷 N.cm 不小于 |
结构 高度 H |
公称 直径 D |
公称 爬电 距离 |
工频 湿耐受 电压 |
工频击穿电压 |
去掉上极地线绝缘子的工频闪络电压kv,不小于 |
地线绝缘子工频(干或湿)放电电压(间隙20mm)kv |
单件重量 kg |
| mm |
kv,不小于 |
干 |
湿 |
上限值 |
下限值 |
| LXDY-70CN |
70 |
565 |
200 |
160 |
160 |
30 |
110 |
45 |
25 |
30 |
8 |
|
| LXDY-100CN |
100 |
678 |
200 |
170 |
170 |
30 |
110 |
45 |
25 |
30 |
8 |
|

|
型 号 |
品 号 |
机械破坏负荷kN不小于 |
公称 结构 高度 H |
绝缘件 公称直径 D |
最小公称 爬电距离 |
雷电全波 冲击耐受 电压 (峰值) kv, 不小于 |
工频电压 (有效值) kv,不小于 |
0.32mg/cm2 盐密下人工污秽闪络电压kv不小于 |
单件 重量 kg |
| 弯曲 |
拉伸 |
mm |
1min 湿闪络 |
击穿 |
| LQBN2-25D |
163102 |
4 |
70 |
610 |
255 |
1260 |
300 |
150 |
- |
31.5 |
17.3 |
| LXY-70T |
132213 |
- |
70 |
146 |
255 |
320 |
100 |
40 |
110 |
- |
3.77 |
| LXHY-70T |
132606 |
- |
70 |
146 |
255 |
400 |
(120) |
(45) |
120 |
- |
4.80 |




|